Valor predictivo de la monitorización antenatal de la F.C.F. según la patología y la edad gestacional

dc.contributor
Universitat de Barcelona. Departament d'Obstetrícia i Ginecologia, Pediatria i Radiologia i Medicina Física
dc.contributor.author
Almirall Oliver, Maria Rosa
dc.date.accessioned
2011-04-12T13:55:45Z
dc.date.available
2005-04-06
dc.date.issued
1988-07-08
dc.date.submitted
2005-04-06
dc.identifier.isbn
8468918911
dc.identifier.uri
http://www.tdx.cat/TDX-0406105-134457
dc.identifier.uri
http://hdl.handle.net/10803/2457
dc.description.abstract
OBJETIVOS: Comparar el valor predictivo de la monitorización antenatal de la F.C.F. respecto al bienestar fetal en función de la patología materna o fetal detectada durante el embarazo, y en función de la edad gestacional en que se realice dicha prueba.<br/><br/>MATERIAL Y MÉTODOS: Para evaluar el valor predictivo de la monitoprización antenatal de la F.C.F. en función de la patología materna o fetal detectada durante el embarazo se relacionan de manera retrospectiva los resultados perinatales con el resultado de la prueba realizada la semana antes del parto en 1944 fetos de 1928 gestantes agrupadas según la patología materna o fetal presente. <br/>Para evaluar el valor predictivo de la monitorización antenatal en función de la edad gestacional se practican de manera prospectiva y con seguimiento lineal pruebas basales de una hora de duración semanal en 50 fetos desde las 28 a las 34 semanas. También se evaluan los resultados perinatales de 205 fetos, que nacieron entre las 28 y 36 semanas y de 1408 fetos nacidos entre las 37 y 41 semanas de gestación, con los resultados de la monitorización antenatal de la F.C.F. practicada la semana antes del parto. Los criterios de interpretación de la monitorización antenatal son la presencia de aceleraciones transitorias como indicativas de normalidad y la presencia de desaceleraciones o disminución de la variabilidad para la sospecha de pérdida de bienestar fetal. Se consideran como fetos con resultados perinatales desfavorables aquellos que presentan como mínimo una de las siguientes condiciones: Muerte perinatal, pH de arteria umbilical inferior a 7,2 o si la arteria se halla colapsada con un pH de vena umbilical inferior a 7,25, un índice de Apgar inferior a 7 a los 5 minutos de vida y/o presencia de retraso de crecimiento intrauterino y líquido amniótico meconial cuando se práctica cesárea electiva<br/>Se realizan estudios de sensibilidad, especificidad, valor predictivo positivo y negativo para los distintos grupos estudiados y análisis comparativos mediante test de Chi cuadrado y test exacto de Fischer.<br/><br/>RESULTADOS: Al analizar el valor predictivo de la monitorización de la F.C.f. en todos los grupos estudiados se observa una buena sensibilidad y valor predictivo de un resultado normal con una especificidad y un valor predictivo de un resultado patológico relativamente bajos. Las patologías materno-fetales en que la monitorización de la F.C.F. es más útil son la isoimmunización Rh, la sospecha clínica o ecográfica de retraso de crecimiento, los malos antecedentes obstétricos, los estados hipertensivos del embarazo y en las gestantes diabéticas con hipertensión sobreañadida. Es de poca utilidad en gestantes diabéticas y en gestantes sin patología por su baja especificidad y valor predictivo de un resultado patológico. La monitorización antenatal en los fetos pretérmino, estableciendo unos nuevos criterios interpretativos en función de la edad gestacional, permite obtener una alta sensibilidad y valor predictivo de un resultado normal, con una especificidad y un valor predictivo de un resultado patológico relativamente reducidos.
spa
dc.description.abstract
<i>Predictive value of antenatal fetal heart rate monitoring (AFHRM) related to pathology and gestational age<br/><br/>OBJECTIVE: To compare predictive value of AFHRM related to maternal or fetal pathology detected during pregnancy or to gestational age on which monitoring is done.<br/><br/>MATERIAL AND METHODS: Perinatal results in 1944 fetuses out of 1928 pregnant women, grouped according to mother or fetal pathology, are retrospectively related with the result of AFHRM the week before delivery in order to evaluate its predictive value. <br/>Fifty fetuses are tested prospectively with AFHRM one hour long on a weekly basis from 28 and 34 weeks. Perinatal results of 205 fetuses born between 28 and 36 weeks gestation and 1408 fetuses born between 37 and 41 weeks gestation are also evaluated and related to AFHRM results within a week before delivery. AFHRM criteria of normality are the presence of transient accelerations and the presence of decelerations or a low variability suggests fetal distress. Perinatal morbidity criteria are: Perinatal death, umbilical arterial pH lower than 7.20, or if artery is collapsed an umbilical vein pH lower of 7.25, Apgar index below 7 at five minutes life and/or presence of intrauterine growth retardation and amniotic meconium staining in elective caesarean.<br/>Studies of sensitivity, specificity, positive and negative predictive value and comparative analysis by means of Chi-square and exact Fischer test are made for the different groups studied.<br/><br/>RESULTS: A good sensitivity and negative predictive value and a low specificity and positive predictive value are observed on all studied groups. Rh isoimmunization, clinical or ecographical suspicion of fetal growth retardation, poor obstetric history, hypertensive diseases, diabetes plus hypertension are pathologies where AFHRM is most useful. AFHRM looks less useful in diabetes without hypertension and in low risk pregnancies because of its low specificity and positive predictive value. AFHRM before term shows a high sensitivity and negative predictive value, with a low specificity and positive predictive value, as long as new interpretative criteria based on gestational age are clearly set.</I>
eng
dc.format.mimetype
application/pdf
dc.language.iso
spa
dc.publisher
Universitat de Barcelona
dc.rights.license
ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.
dc.source
TDX (Tesis Doctorals en Xarxa)
dc.subject
Preterme
dc.subject
Patología gestacional
dc.subject
Monitorització antenatal
dc.subject
Freqüència cardiaca fetal
dc.subject.other
Ciències de la Salut
dc.title
Valor predictivo de la monitorización antenatal de la F.C.F. según la patología y la edad gestacional
dc.type
info:eu-repo/semantics/doctoralThesis
dc.type
info:eu-repo/semantics/publishedVersion
dc.subject.udc
618
cat
dc.contributor.authoremail
ralmirall@menta.net
dc.contributor.director
González Merlo, Jesús
dc.rights.accessLevel
info:eu-repo/semantics/openAccess
cat
dc.identifier.dl
B.21973-2005


Documents

TESI_01.PDF

420.1Kb PDF

TESI_02.PDF

252.6Kb PDF

TESI_03.PDF

641.6Kb PDF

TESI_04.PDF

583.5Kb PDF

TESI_05.PDF

568.7Kb PDF

TESI_06.PDF

554.9Kb PDF

TESI_07.PDF

237.7Kb PDF

TESI_08.PDF

357.2Kb PDF

TESI_09.PDF

46.71Kb PDF

This item appears in the following Collection(s)