Utilidad intraoperatoria de la ecocardiografía transesofágica tridimensional en la reparación de la válvula mitral

Author

Hernández Martínez, Alberto

Director

Aguilar Torres, Río

Roigé i Solé, Jaume

Armengol Carrasco, Manuel

Date of defense

2016-02-10

ISBN

9788449062742

Pages

217 p.



Department/Institute

Universitat Autònoma de Barcelona. Departament de Cirurgia

Abstract

Objetivo; Se ha utilizado la ecocardiografía transesofágica intraoperatoria en cirugía de reparación de la válvula mitral, y se han comparado los modos ecocardiográficos bidimensional (Eco2D) y tridimensional (Eco3D) con el fin de evaluar si la Eco3D es superior a la Eco2D, para la detección y localización precisa de prolapsos valvulares, rotura de cuerdas (flail) y detección de hendiduras (cleft). Métodos; Se estudiaron de manera prospectiva 90 pacientes que se sometieron a reparación de la válvula mitral, ya fuese como procedimiento único o asociado. La válvula fue inspeccionada por el cirujano y sus hallazgos considerados como el “gold standard” y por tanto determinaron la precisión diagnóstica. Para cada paciente se realizó intraoperatoriamente mediante la utilización de una sonda transesofágica 3D, un estudio ecocardiográfico completo y detallado, tanto en modo bidimensional (2D) como en modo tridimensional (3D) y se grabaron todas las imágenes. Resultados; La inspección quirúrgica de la válvula realizada por el cirujano, detectó la presencia de prolapso en 72 de las 90 válvulas inspeccionadas. La presencia o ausencia de prolapso valvular mitral se diagnosticó correctamente en 81 de los casos con una precisión del 90% cuando se utilizó la Eco3D, y en 71 de los casos cuando se aplicó la Eco2D con una precisión diagnóstica del 78.89%. La Eco3D se asoció más intensamente con los hallazgos quirúrgicos que la Eco2D para la detección de prolapsos valvulares (diferencia de proporciones = 11,1%; IC [1,56%, 22,18%], p=0,042). Además, cuando se hizo un análisis por segmentos o festones valvulares, la Eco3D fue significativamente más precisa en detectar prolapsos de los segmentos A2 (diferencia de proporciones = 10.0%, IC [3.43%, 18.36%], p = 0.012), A3 (diferencia de proporciones = 7.78%, IC [1,59%, 16,67%], p =0.039), P1 (diferencia de proporciones = 8.36%, IC [4.35%, 19.67%], p = 0.006), y P2 (diferencia de proporciones = 14.45%, IC [7,13%, 23,55%], p = 0.001). La inspección quirúrgica también reveló la presencia de ruptura cordal en 53 casos. La presencia o ausencia de rotura de cuerdas se diagnosticó correctamente en 85 de los casos con una precisión del 94,44% cuando se utilizó la Eco3D, y en 64 de los casos cuando se aplicó la Eco2D con una precisión diagnóstica del 71,11% (diferencia de proporciones = 23,33%; IC [13,85%, 33,71%], p < 0.001). El análisis por segmentos evidenció superioridad de la Eco3D para detectar la ruptura cordal para los segmentos A2 (diferencia de proporciones = 10.0%, IC [2,85%, 10.86%], p =0.004), P1 (diferencia de proporciones = 8,8 %, IC [1,58%, 17.46%], p =0.039, y P2 (diferencia de proporciones = 19,89 %, IC [10,87 %, 28.54%], p = 0.0001). Conclusión: Aunque la Eco2D sigue siendo actualmente la herramienta estándar intraoperatoria como estudio de imagen de la válvula mitral, la Eco3D mejora la visualización de la patología valvular y aumenta la precisión diagnóstica facilitada por la orientación espacial que permite este modo tridimensional de imagen.


Objective; We used the intraoperative transesophageal echocardiography in mitral valve repair surgery, and compared both echocardiographic modes (Eco2D versus Eco3D) in order to assess whether Eco3D is superior to Eco2D, for detection and accuracy of location of valve prolapse, chordal rupture (flail) and cleft. Methods; 90 patients have undergone repair surgery of mitral valve as a single or associated procedure were studied prospectively. The valve was inspected by surgeons and theirs findings were considered the “gold standard” and thus determined the accuracy. For each patient a comprehensive intraoperative transesophageal study was performed using a 3D probe, a complete and detailed, two-dimensional and three-dimensional echocardiography study were performed and all pictures were recorded. Results; Surgical inspection detected the presence of prolapse in 72 of the 90 valves inspected. In 18 patients no presence of prolapsed was found as a cause of valvular insufficiency. The presence or absence of mitral valve prolapsed was diagnosed correctly in 81 cases with an accuracy of 90% when Eco3D was used and in 71 cases Eco2D when applied with an accuracy of 78.89%. The Eco3D correlated more strongly with surgical findings than Eco2D (difference of proportions = 11,1%; IC [1,56%, 22,18%], p=0,042). Furthermore, when the different scallops of the valve were analysed, the Eco3D was significantly better for detecting prolapses in the scallops A2 (difference in proportions = 10.0%, CI [3.43%, 18.36%], p = 0.012), A3 (difference in proportions = 7.78%, CI [1,59%, 16,67%], p =0.039), P1 (difference in proportions = 8.36%, CI [4.35%, 19.67%], p = 0.006), and P2 (difference in proportions = 14.45% CI [7.12% 23.54%], p = 0.0010). Surgical inspection also identified 53 and 37 patients with and without chordal rupture, respectively. Eco3D correctly diagnosed the presence or absence of chordal rupture in 85 of these patients (94.44%) as opposed to 43 patients (71.11% ) using Eco2D (difference in proportions = 23.33% CI [13.85%, 33.71%], p <0.001). The analysis by scallop showed that the accuracy of Eco3D was significantly higher for the most frequent lesions; scallop A2 (difference in proportions = 10.0% CI [2.85% 10.86%], p = 0.004), scallop P1 (difference in proportions = 8,8 %, CI [1,58%, 17.46%], p =0.039), and scallop P2 (difference in proportions = 19,89 %, CI [10,87 %, 28.54%], p = 0.0001). Conclusion: Although Eco2D remains the standard tool as intraoperative imaging for studying mitral valve, the Eco3D improves visualization of the valve pathology and increases the accuracy of the interpretation facilitated by the spatial orientation that allows the three-dimensional image mode.

Keywords

Ecocardiografia tridimensional; Tridimensional echocardiography; Reparación valvular mitral; Mitral valve repair

Subjects

61 - Medical sciences

Knowledge Area

Ciències de la Salut

Documents

ahm1de1.pdf

6.258Mb

 

Rights

L'accés als continguts d'aquesta tesi queda condicionat a l'acceptació de les condicions d'ús establertes per la següent llicència Creative Commons: http://creativecommons.org/licenses/by-nc-nd/3.0/es/
L'accés als continguts d'aquesta tesi queda condicionat a l'acceptació de les condicions d'ús establertes per la següent llicència Creative Commons: http://creativecommons.org/licenses/by-nc-nd/3.0/es/

This item appears in the following Collection(s)